LCD DISPLAY
The LCD displays event information, status information, and the option menus. It has two lines of
text, each with 40 characters , and is backlit when there is an active event on the system or the
menu options are accessed. In the normal operating mode the backlight is dim and the top line
displays a default text message or user-defined text. The second line displays the current time
and date, e.g.
When an event occurs, the backlight is activated and the LCD shows the event details, e.g.
The display shows the event type, i.e. Fire, the zone that the activated device is in, i.e. zone 1,
and the number of events, i.e. 1. The bottom line alternates with the device location text (if pro-
grammed)
Pressing button
[1]
reveals the device information, Type, i.e manual call point, address number
and time and date of the event. This button will function regardless of status of keyswitch.
NOTE
: Fault conditions on the system are suppressed when Fire events are present. The
GEN-
ERAL FAULT LED
is illuminated and faults can be viewed if required via the 'View Active Faults'
option - when button
[1]
is pressed.
The bottom line displays a text message describing the device location.
In the menu mode, menu options are displayed as follows:
The Keypad is used to navigate through the menu options and select functions as described in
the installation and commissioning manual.
FUSION PANEL
SYSTEM NORMAL 9:36 15/03/04
FIRE ZONE 01 OF 01 Z0NES 01 OF 01
PANEL 01 RECENT ZONE 01
SELECT MENU OPTION