99
OPTIONAL EQUIPMENT CHARGE BYPASS UNIT
■
Optional Equipment Charge Bypass Unit (CBU-600)
○
Summary:
The Charge Bypass Unit is used when the work’s internal volume is large, requiring a large amount
of charged air in order to maintain testing stability with a shortened testing time.
Explanations in this manual are done under the assumption that the master is a standard part. If
foreign material could enter into the master (such as from the work or work comparison,) take proper
precautions to ensure that this does not happen. (This option is not available in the H1 range).
○
External View
○
Installation Dimensions (Not including projecting items)
For details, please refer to the Charge Bypass Unit External View supplement in the back of this
manual.
○
EXT VALVE SIGNAL Cable Wiring
Connection
Tester Side
(EXH SIGNAL)
Charge Bypass Side
(EXH SIGNAL)
Applied Connector
MR-34LF
JR16WR-7P
Remarks
1
-
1
23
-
2
Pressure Valve
2
-
3
24
-
4
Exhaust Valve
10
13
19
Pin Number
32
Applied
Connector
(Included)
Plug JR16WR-7P
Receptacle JR16WP-7S
Applied Cable
At least 0.3SQ
Label
Warning
・
Do not remove the CBU cover.
・
Some parts within the CBU carry a high voltage and
may be driven unexpectedly due to the tester’s mechanical
sequences. Possible electric shock and injuries may
occur if this warning is ignored. Only qualified
maintenance personnel should service this machine.
82
4-M5
Approx 41
128
142.5
64
Height 113mm
Jumper
Summary of Contents for FL-601 Series
Page 10: ...9 OUTLINE ...
Page 17: ...16 OUTLINE ADDITIONAL EQUIPMENT MEMO ...
Page 18: ...17 PRINCIPLE ...
Page 24: ...23 POWER ON PROCEDURE ...
Page 50: ...49 BASIC OPERATION ...
Page 59: ...58 TESTING OPERATION ...
Page 68: ...67 MAINTNANCE FUNCTIONS ...
Page 92: ...91 OPTIONAL EQUIPMENT ...
Page 108: ...111 SUPPLEMENT ...
Page 112: ...111 SUPPLEMENT ...
Page 116: ...115 SUPPLEMENT Pneumatic Circuit Diagram FL 601UL L M H1Pneumatic Circuit Diagram ...
Page 119: ...118 SUPPLEMENT Pneumatic Circuit Diagram ChargeBypassUnit CBU 600C Exhaust Valve ...