DIP SW
Interface card
LED2
(green)
LED1
(red)
OFF
ON
figure 1 - Location of DIP switches and diodes
on the hydraulic unit interface card
LED display
Error contents
LED 2 (green)
LED 1 (red)
1 Flash
1 Flash
Communication error between Hydraulic unit and Outdoor unit
2 Flashs
3 Flashs
Connection forbidden (series error)
3 Flashs
1 Flash
Indoor unit power supply abnormal
3 Flashs
2 Flashs
Serial communication error between Controller /Interface PCBs
4 Flashes
1 Flash
Heat pump capacity signal error (Open or short)
4 Flashes
2 Flashes
Hydraulic unit heat-exchange thermistor Error
6 Flashs
1 Flash
Outdoor unit power supply abnormal
6 Flashs
2 Flashs
Outdoor unit main PCB error
6 Flashes
3 Flashes
Inverter error
6 Flashes
4 Flashes
Active filter error.
6 Flashs
5 Flashs
Outdoor unit IPM error
6 Flashs
7 Flashs
Outdoor unit power short interruption error (protective operation)
6 Flashs
8 Flashs
Outdoor unit magnetic relay error
7 Flashes
1 Flash
Discharge thermistor error
7 Flashes
2 Flashes
Compressor thermistor error
7 Flashes
3 Flashes
Heat-exchange thermistor (outlet / intermediate) error
7 Flashes
4 Flashes
Outdoor thermistor error
7 Flashs
7 Flashs
Outdoor unit heat sink temp thermistor error
7 Flashes
8 Flashes
Expansion valve thermistor error
8 Flashes
4 Flashes
Current sensor error
8 Flashes
6 Flashes
Pressure sensor error / Pressure switch error
9 Flashes
4 Flashes
Current trip
9 Flashes
5 Flashes
Detection of compressor position error / Compressor start up error
9 Flashes
7 Flashes
Outdoor unit fan motor error
10 Flashes
1 Flash
Discharge temperature protection
10 Flashes
3 Flashes
Compressor temperature protection
10 Flashs
4 Flashs
Outdoor unit pressure error
10 Flashes
5 Flashes
Low pressure abnormal
10 Flashs
9 Flashs
Current overload error
Continuous flashing (1 sec On / 1 sec Off)
Pump down operation
Continuous lighting
Off
Defrosting