3-38
SPARC Enterprise T2000 Server Service Manual • April 2007
3.4.5.2
Determining When to Replace Detected Devices
Note –
This section assumes faults are detected by POST in maximum mode.
If a detected device is part of a hardware upgrade or repair, or if POST detects
multiple DIMMs (
), replace the detected devices.
Note –
The previous example shows two DIMMs on the same channel/rank, which
could be an uncorrectable error.
If the detected device is
not
a part of a hardware upgrade or repair, use the following
list to examine and repair the fault:
1. If a detected device is not a DIMM, or if more than a single DIMM is detected,
replace the detected devices.
2. If a detected device is a single DIMM and the same DIMM is also detected by
PSH, replace the DIMM (
Note –
The detected DIMM in the previous example must also be replaced because
it exceeds the PSH page retire threshold.
CODE EXAMPLE 3-2
POST Fault for Multiple DIMMs
sc>
showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0 deemed
faulty and disabled
2 OCT 13 12:47:27 MB/CMP0/CH0/R0/D1 MB/CMP0/CH0/R0/D1 deemed
faulty and disabled
CODE EXAMPLE 3-3
PSH and POST Faults on the Same DIMM
sc>
showfaults -v
ID Time FRU Fault
0 SEP 09 11:09:26 MB/CMP0/CH0/R0/D0 Host detected fault,
MSGID:SUN4V-8000-DX UUID: 7ee0e46b-ea64-6565-e684-e996963f7b86
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0 deemed
faulty and disabled
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......