5-16
SPARC Enterprise T2000 Server Service Manual • April 2007
c. Switch to the system console to view POST output.
Watch the POST output for possible fault messages. The following output is a
sign that POST did not detect any faults:
Note –
Depending on the configuration of ALOM CMT POST variables and
whether POST detected faults or not, the system might boot, or the system might
remain at the
ok
prompt. If the system is at the
ok
prompt, type
boot
.
d. Return the virtual keyswitch to normal mode.
e. Issue the Solaris OS
fmadm faulty
command.
No memory or DIMM faults should be displayed.
If faults are reported, refer to the diagnostics flowchart in
for an approach
to diagnose the fault.
9. Gain access to the ALOM CMT
sc>
prompt.
10. Run the
showfaults
command.
sc>
console
.
.
.
0:0>POST Passed all devices.
0:0>
0:0>DEMON: (Diagnostics Engineering MONitor)
0:0>Select one of the following functions
0:0>POST:Return to OBP.
0:0>INFO:
0:0>POST Passed all devices.
0:0>Master set ACK for vbsc runpost command and spin...
sc>
setkeyswitch normal
#
fmadm faulty
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......