6-2
SPARC Enterprise T2000 Server Service Manual • April 2007
motherboard (an
onboard
hard drive controller). Regardless of the type of controller,
the hard drives are installed into the chassis the same way as described in this
procedure.
Note –
Not all servers have the on-board hard drive controller support. These
servers have the PCI-X SAS controller card installed.
1. Remove the blank panel from the chassis:
a. On the blank panel, push the latch release button.
b. Grasp the latch and pull the blank panel out.
2. Align the disk drive to the drive bay slot.
See
. For additional details, see
Section 4.5.1, “Removing a Hard Drive” on
.
3. Slide the hard drive into the bay until the drive is fully seated.
4. Close the hard drive lever to lock the drive in place.
5. Use
cfgadm -al
to list all disks in the device tree, including unconfigured disks.
If the disk is not in list, such as with a newly installed disk, then use
devfsadm
to
configure it into the tree. See the
devfsadm
man page for details.