Chapter 3
Server Diagnostics
3-25
3.3.4
Running the
showfru
Command
The
showfru
command displays information about the FRUs in the server. Use this
command to see information about an individual FRU, or for all the FRUs.
Note –
By default, the output of the
showfru
command for all FRUs is very long.
●
At the
sc>
prompt, enter the
showfru
command.
In the following example, the
showfru
command is used to get information about
the motherboard (MB).
sc>
showfru MB.SEEPROM
SEGMENT: SD
/ManR
/ManR/UNIX_Timestamp32: WED OCT 12 18:24:28 2005
/ManR/Description:
ASSY,SPARC-Enterprise-T2000,CPU Board
/ManR/Manufacture Location: Sriracha,Chonburi,Thailand
/ManR/Sun Part No: 5016843
/ManR/Sun Serial No: NC00OD
/ManR/Vendor: Celestica
/ManR/Initial HW Dash Level: 06
/ManR/Initial HW Rev Level: 02
/ManR/Shortname: T2000_MB
/SpecPartNo: 885-0483-04
SEGMENT: FL
/Configured_LevelR
/Configured_LevelR/UNIX_Timestamp32:
WED OCT 12 18:24:28 2005
/Configured_LevelR/Sun_Part_No: 5410827
/Configured_LevelR/Configured_Serial_No: N4001A
/Configured_LevelR/HW_Dash_Level: 03
.
.
.
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......