Chapter 3
Server Diagnostics
3-37
3.4.5.1
Correctable Errors for Single DIMMs
If POST faults a single DIMM (
) that was not part of a hardware
upgrade or repair, it is likely that POST encountered a correctable error that can be
handled by PSH.
In this case, reenable the DIMM and run POST in minimum mode as follows:
1. Reenable the DIMM.
2. Return POST to minimum mode.
3. Reset the system so that POST runs.
There are several ways to initiate a reset. The following example uses the
powercycle
command. For other methods, refer to the
SPARC Enterprise T2000
Server Administration Guide
.
4. Replace the DIMM if POST continues to fault the device in minimum mode.
CODE EXAMPLE 3-1
POST Fault for a Single DIMM
sc>
showfaults -v
ID Time FRU Fault
1 OCT 13 12:47:27 MB/CMP0/CH0/R0/D0 MB/CMP0/CH0/R0/D0 deemed
faulty and disabled
sc>
enablecomponent
name-of-DIMM
sc>
setkeyswitch normal
sc>
setsc diag_mode normal
sc>
setsc diag_level min
sc>
powercycle
Are you sure you want to powercycle the system [y/n]?
y
Powering host off at MON JAN 10 02:52:02 2000
Waiting for host to Power Off; hit any key to abort.
SC Alert: SC Request to Power Off Host.
SC Alert: Host system has shut down.
Powering host on at MON JAN 10 02:52:13 2000
SC Alert: SC Request to Power On Host.
Summary of Contents for SPARC Enterprise T2000
Page 1: ......
Page 2: ......
Page 6: ......
Page 16: ...xiv SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 18: ...xvi SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 27: ...Preface xxv Reader s Comment Form ...
Page 43: ...Chapter 3 Server Diagnostics 3 3 FIGURE 3 1 Diagnostic Flow Chart flowchart ...
Page 106: ...4 12 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 152: ...5 46 SPARC Enterprise T2000 Server Service Manual April 2007 ...
Page 173: ......
Page 174: ......