A26361-K523-Z100-6-7619
57
Technical data
Electrical data
Regulations complied with:
EN 60950 / VDE 0805
UL 1950
CSA 22.2 No.950
Protection class:
I
Rated voltage range: (selectable)
100 V - 127 V / 200 V - 240 V
Frequency:
50 Hz - 60 Hz
Max. rated current
·
PC with monitor socket:
·
Monitor socket (output)
100 V -127 V/4,0 A
200 V -240 V/2,0 A
100 V -127 V/3 A
200 V -240 V/1,5 A
Maximum power draw in operation:
(running Systest program under W98)
Minimum power draw in operation:
(running W98 without additional application)
Power draw in energy saving mode:
(ACPI S3 mode)
Power draw in the 'ready-to-operate' status:
Power draw in the switched-off state:
(Power switch at backside of the system)
66 W *)
33 W *)
2,1 W *)
2,1 W *)
0 W
Noise emission:
SCENIC S
during operation:
Operation Mode (Neighbouring station):
Idle Mode:
Idle Mode (Neighbouring station):
SCOVERY xS (with closed front bezel)
during operation:
Operation Mode (Neighbouring station):
Idle Mode:
Idle Mode (Neighbouring station):
Sound power level (L
WAd
) 43 dB (A) *)
Sound pressure level (L
LpAm
) 29dB (A) *)
Sound power level (L
WAd
) 38 dB (A) *)
Sound pressure level (L
LpAm
) 24dB (A) *)
Sound power level (L
WAd
) 36 dB (A)
Sound pressure level (L
LpAm
) 21dB (A)
Sound power level (L
WAd
) 35 dB (A)
Sound pressure level (L
LpAm
) 20dB (A)
*)
These values only apply for a SCENIC S / SCOVERY xS with the configuration below. When
additional or other components are incorporated, the power consumption or the sound
emission (L
WAd
) in energy saving mode may exceed the requirements for the environment
symbol ("Blue Angel") (30 W or 55 dB).