Important information
●
Do not damage or modify internal cables or devices. Doing so may cause a
device failure, fire, or electric shock and will void the warranty and exempt
the manufacturer from all liability.
●
Devices inside the server remain hot after shutdown. Wait for a while after
shutdown before installing or removing internal options.
●
The circuit boards and soldered parts of internal options are exposed and
can be damaged by static electricity. To ensure reliable protection, if you are
wearing an earthing band on your wrist when working with this type of
module, connect it to an unpainted, non-conducting metal part of the system.
●
Do not touch the circuitry on boards or soldered parts. Hold the metallic
areas or the edges of the circuit boards.
●
Install the screw removed during installation/detaching internal options in
former device/position. To use a screw of the different kind can cause a
breakdown of equipment.
●
The installation indicated on this document is sometimes changed to the
kind of possible options without notice.
Batteries
●
Incorrect replacement of batteries may lead to a risk of explosion. The
batteries may only be replaced with identical batteries or with a type
recommended by the manufacturer.
●
Do not throw batteries into the trash can.
●
Batteries must be disposed of in accordance with local regulations
concerning special waste.
●
Make sure that you insert the battery the right way round.
●
The battery used in this device may present a fire or chemical burn hazard
if mistreated. Do not disassemble, heat about 100 °C (212F), or incinerate
the battery.
●
All batteries containing pollutants are marked with a symbol (a crossed-out
garbage can). In addition, the marking is provided with the chemical symbol
of the heavy metal decisive for the classification as a pollutant:
Cd Cadmium
Hg Mercury
Pb Lead
Summary of Contents for PRIMERGY TX100 S3
Page 16: ...TX100 S3 Upgrade and Maintenance Manual Version history ...
Page 40: ...40 Upgrade and Maintenance Manual TX100 S3 Important information ...
Page 68: ...68 Upgrade and Maintenance Manual TX100 S3 Basic hardware procedures ...
Page 86: ...86 Upgrade and Maintenance Manual TX100 S3 Basic software procedures ...
Page 104: ...104 Upgrade and Maintenance Manual TX100 S3 Power supply ...
Page 126: ...126 Upgrade and Maintenance Manual TX100 S3 Hard disk drives ...
Page 146: ...146 Upgrade and Maintenance Manual TX100 S3 System fan modules ...
Page 200: ...200 Upgrade and Maintenance Manual TX100 S3 Expansion cards and backup units ...
Page 234: ...234 Upgrade and Maintenance Manual TX100 S3 Processor ...
Page 272: ...272 Upgrade and Maintenance Manual TX100 S3 Accessible drives ...
Page 288: ...288 Upgrade and Maintenance Manual TX100 S3 Front panel and external connectors ...