80
Upgrade and Maintenance Manual
TX100
S3
Basic software procedures
5.2.8
Updating the NIC configuration file in a Linux
environment
In order to prevent errors caused by changing network device names (
eth<x>
),
it is recommended to store the MAC address (hardware address) of a network
interface card in the related NIC configuration file of the Linux OS.
When replacing a network controller or the system board with onboard LAN
controllers in a server running Linux OS, the MAC address will change but not
automatically be updated in the definition file.
In order to prevent communication problems, it is necessary to update the
changed MAC address stored in the related
ifcfg-eth<x>
definition file.
To update the MAC address, proceed as follows:
I
Procedures may differ depending on your Linux OS or the definition file
on the client system. Use the following information as reference. Ask the
system administrator to change the definition file.
Ê
After replacing a network controller or the system board, switch on and boot
the server as described in section
"Switching on the server" on page 60
.
kudzu
, the hardware configuration tool for Red Hat Linux, will launch at boot
and detect the new and / or changed hardware on your system.
I
kudzu
may not launch at boot depending on the client’s environment.
Ê
Select
Keep Configuration
and
Ignore
to complete the boot process.
Ê
Use the
vi
text editor to specify the MAC address in the
HWADDR
section of
the
ifcfg-eth<x>
file:
I
The MAC address can be found on the type label attached to the
system board or network controller.
Example:
In order to modify the definition file for network controller 1, enter the
following command:
# vi /etc/sysconfig/network-scripts/ifcfg-eth1
In
vi
, specify the new MAC address as follows:
HWADDR=xx:xx:xx:xx:xx:xx
Summary of Contents for PRIMERGY TX100 S3
Page 16: ...TX100 S3 Upgrade and Maintenance Manual Version history ...
Page 40: ...40 Upgrade and Maintenance Manual TX100 S3 Important information ...
Page 68: ...68 Upgrade and Maintenance Manual TX100 S3 Basic hardware procedures ...
Page 86: ...86 Upgrade and Maintenance Manual TX100 S3 Basic software procedures ...
Page 104: ...104 Upgrade and Maintenance Manual TX100 S3 Power supply ...
Page 126: ...126 Upgrade and Maintenance Manual TX100 S3 Hard disk drives ...
Page 146: ...146 Upgrade and Maintenance Manual TX100 S3 System fan modules ...
Page 200: ...200 Upgrade and Maintenance Manual TX100 S3 Expansion cards and backup units ...
Page 234: ...234 Upgrade and Maintenance Manual TX100 S3 Processor ...
Page 272: ...272 Upgrade and Maintenance Manual TX100 S3 Accessible drives ...
Page 288: ...288 Upgrade and Maintenance Manual TX100 S3 Front panel and external connectors ...