94
Upgrade and Maintenance Manual
RX300
S8
Basic software procedures
I
Procedures may differ depending on your Linux OS or the definition file
on the client system. Use the following information as reference. Ask the
system administrator to change the definition file.
Ê
After replacing a network controller or the system board, switch on and boot
the server as described in section
"Switching on the server" on page 71
.
kudzu
, the hardware configuration tool for Red Hat Linux, will launch at boot
and detect the new and / or changed hardware on your system.
I
kudzu
may not launch at boot depending on the client’s environment.
Ê
Select
Keep Configuration
and
Ignore
to complete the boot process.
Ê
Use the
vi
text editor to specify the MAC address in the
HWADDR
section of
the
ifcfg-eth<x>
file:
I
The MAC address can be found on the type label attached to the
system board or network controller.
Example:
In order to modify the definition file for network controller 1, enter the
following command:
# vi /etc/sysconfig/network-scripts/ifcfg-eth1
In
vi
, specify the new MAC address as follows:
HWADDR=xx:xx:xx:xx:xx:xx
Ê
Save and close the definition file.
Ê
For the changes to take effect, you need to reboot the network by entering
the following command:
# service network restart
I
If the system board or network controller offers multiple LAN ports, it is
necessary to update the remaining
ifcfg-eth<x>
definition files
accordingly.
Ê
Update the NIC configuration file to reflect the new card sequence and MAC
address.
Summary of Contents for PRIMERGY RX300 S8
Page 24: ...Upgrade and Maintenance Manual RX300 S8 Contents ...
Page 38: ...38 Upgrade and Maintenance Manual RX300 S8 Before you start ...
Page 72: ...72 Upgrade and Maintenance Manual RX300 S8 Basic hardware procedures ...
Page 158: ...158 Upgrade and Maintenance Manual RX300 S8 Hard disk drives solid state drives ...
Page 166: ...166 Upgrade and Maintenance Manual RX300 S8 System fan ...
Page 242: ...242 Upgrade and Maintenance Manual RX300 S8 Expansion cards and backup units ...
Page 260: ...260 Upgrade and Maintenance Manual RX300 S8 Main memory ...
Page 296: ...296 Upgrade and Maintenance Manual RX300 S8 Processors ...
Page 482: ...482 Upgrade and Maintenance Manual RX300 S8 Cables ...
Page 502: ...502 Upgrade and Maintenance Manual RX300 S8 Appendix ...