
136
Upgrade and Maintenance Manual
RX300
S8
Hard disk drives / solid state drives
7.3.2.1
Preliminary steps
Ê
Locate the correct drive bay as described in section
"Mounting order for 2.5-
inch HDDs / SSDs" on page 131
.
7.3.2.2
Removing a 2.5-inch dummy module
Figure 44: Removing a 2.5-inch dummy module
Ê
Press both tabs together (1) and pull the dummy module out of its bay (2).
V
CAUTION!
Save the dummy module for future use.
Always replace dummy modules into unused HDD / SSD bays to
comply with applicable EMC regulations and satisfy cooling
requirements.
Summary of Contents for PRIMERGY RX300 S8
Page 24: ...Upgrade and Maintenance Manual RX300 S8 Contents ...
Page 38: ...38 Upgrade and Maintenance Manual RX300 S8 Before you start ...
Page 72: ...72 Upgrade and Maintenance Manual RX300 S8 Basic hardware procedures ...
Page 158: ...158 Upgrade and Maintenance Manual RX300 S8 Hard disk drives solid state drives ...
Page 166: ...166 Upgrade and Maintenance Manual RX300 S8 System fan ...
Page 242: ...242 Upgrade and Maintenance Manual RX300 S8 Expansion cards and backup units ...
Page 260: ...260 Upgrade and Maintenance Manual RX300 S8 Main memory ...
Page 296: ...296 Upgrade and Maintenance Manual RX300 S8 Processors ...
Page 482: ...482 Upgrade and Maintenance Manual RX300 S8 Cables ...
Page 502: ...502 Upgrade and Maintenance Manual RX300 S8 Appendix ...