RX300 S8
Upgrade and Maintenance Manual
93
Basic software procedures
Viewing the SEL using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Event Log
and choose the
Internal Event Log
submenu.
Ê
Under
Internal Event Log Content
the SEL is being displayed. In order to filter
the list, select the check boxes next to the desired event types and press
Apply
for the changes to take effect.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.11.2 Clearing the SEL
You can clear the System Event Log (SEL) using the ServerView iRMC web
frontend:
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
Event Log
and choose the
Internal Event Log
submenu.
Ê
Under
Internal Event Log Information
click
Clear Internal Event Log
to clear the
SEL.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
5.2.12 Updating the NIC configuration file in a Linux
environment
In order to prevent errors caused by changing network device names (
eth<x>
),
it is recommended to store the MAC address (hardware address) of a network
interface card in the related NIC configuration file of the Linux OS.
When replacing a network controller or the system board with onboard LAN
controllers in a server running Linux OS, the MAC address will change but not
automatically be updated in the definition file.
In order to prevent communication problems, it is necessary to update the
changed MAC address stored in the related
ifcfg-eth<x>
definition file.
To update the MAC address, proceed as follows:
Summary of Contents for PRIMERGY RX300 S8
Page 24: ...Upgrade and Maintenance Manual RX300 S8 Contents ...
Page 38: ...38 Upgrade and Maintenance Manual RX300 S8 Before you start ...
Page 72: ...72 Upgrade and Maintenance Manual RX300 S8 Basic hardware procedures ...
Page 158: ...158 Upgrade and Maintenance Manual RX300 S8 Hard disk drives solid state drives ...
Page 166: ...166 Upgrade and Maintenance Manual RX300 S8 System fan ...
Page 242: ...242 Upgrade and Maintenance Manual RX300 S8 Expansion cards and backup units ...
Page 260: ...260 Upgrade and Maintenance Manual RX300 S8 Main memory ...
Page 296: ...296 Upgrade and Maintenance Manual RX300 S8 Processors ...
Page 482: ...482 Upgrade and Maintenance Manual RX300 S8 Cables ...
Page 502: ...502 Upgrade and Maintenance Manual RX300 S8 Appendix ...