Conversion configurations
Figure 309: Connecting SAS cables
Ê
Connect cable C5 to the connector X17 of the 12x 2.5-inch SAS
backplane (1).
Ê
Connect cable C4 to the connector X15 of the 12x 2.5-inch SAS
backplane (2).
Ê
Connect the cable C9 to X1 of the 12x 2.5-inch SAS backplane (3) and the
connector MLC1 of the SAS controller (4).
Ê
Connect the cable C9 to X2 of the 12x 2.5-inch SAS backplane (5) and the
connector MLC2 of the SAS controller (6).
Ê
Route the cables as shown.
15.3.3 Configuration 2 to configuration 3
I
The configuration 2 must include a SAS controller. Otherwise you must
install a SAS controller as described in section
"Installing the SAS RAID
controller" on page 190
.