68
Upgrade and Maintenance Manual
RX300
S8
Basic hardware procedures
4.5.3.2
Sliding the server into the rack
Figure 12: Sliding the server into the rack
Ê
Pull up on the locking latch on both telescopic rails (1).
Ê
Slide the server inside the rack as far as it will go (2) until the quick release
levers on the rack mounting frame lock into place.
Ê
Reconnect all cables except the power cord to the server rear.
I
If you are not using a cable mounting arm (CMA kit), ensure that the
rear cables are long enough not to be strained or damaged when
extending the server out of the rack.
Use cable ties to prevent loose cables from blocking the air flow.
For information on connecting and securing the power cord, refer to section
"Connecting the server to the power source" on page 69
.