RX300 S8
Upgrade and Maintenance Manual
33
Before you start
Screw driver /
Bit insert /
torque
Screw
Usage
Type
Phillips
PH2 / (+) No. 2
hexagonal cross
SW5 / PZ2
0.6 Nm
HDD cages
to chassis
RDX/DAT
cage in 3.5"
variant
(A100)
Slot bracket
to chassis
Fan box
M3 x 4.5 mm
(silver)
C26192-Y10-C67
Phillips
PH2 / (+) No. 2
hexagonal cross
SW5 / PZ2
0.6 Nm
System
board
Front panel
M3 x 6 mm
(silver)
C26192-Y10-C68
Torx
TX10
0.6 Nm
3.5-inch HDD
UNC
6-32 x 4.76 mm
(silver)
C26192-Y10-C27
Phillips
PH0 / (+) No. 0
0.4 Nm
2.5-inch
HDD/SSDs
RDX/DAT in
2.5-inch
variant
LTO drive
M3 x 3.5 mm
Wafer head screw
(silver)
C26192-Y10-
C102
Table 2: List of required tools and used screws