![background image](http://html.mh-extra.com/html/fujitsu/primergy-rx100-s2/primergy-rx100-s2_user-manual_121067242.webp)
242
Chapter 9 Operation and Maintenance
■
Deleting the System Event Log
1
Start Server Management Tools.
The menu window of Server Management Tools appears.
2
Use the [
↑
] and [
↓
] keys to select [System Event Log (SEL)], and press the
[Enter] key.
The [SYSTEM EVENT LOG (SEL)] window appears.
3
Press the [F3] key.
The confirmation window appears.
4
Press the [Enter] key.
This deletes the system event log.
Selecting [System Event Log (SEL)] right after deleting the system event log will result in an error.
Allow approximately 10 seconds to select it normally.
9.3.4 Before Using the Remote Control Service
Perform the following procedures before using the Remote Control Service.
1
Check the following settings by starting the BIOS Setup Utility, and correct them
if incorrect.
• The [Peripheral Configuration] submenu of the [Advanced] menu
"8.2.6 Peripheral Configuration Submenu" (pg.200)
• The [Console Redirection] submenu of the [Server] menu
"8.2.15 Console Redirection Submenu" (pg.214)
table: Setup on the Peripheral Configuration Submenu
Item
Setting
Serial Enabled
Base I/O address
3F8/IRQ 4
Serial Multiplexer
Shared
table: Setup on the Console Redirection submenu
Item
Setting
Console Redirection
Port
Enabled
Baud Rate
115.2K
Media Type
LAN
Protocol
VT100+
Flow Control
None
Mode
Enhanced