MMB CLI (Command Line Interface) Operations
2.6 PRIMEQUEST 2800B2/2800B model Commands
531
CA92344-0539-04
2.6.36 start raid mdc
Starts make data consistency (MDC) to the specified logical drive.
Privilege: Administrator, Operator, Partition Operator (Only managed partition)
(1) Input format
start raid mdc [SB | DU | IOU | PCI_BOX] <UNIT#>-<PCISLOT#> target=<TargetID>
{force}
(2) Option
target: This option specifies targetID of the logical drive. (ex. target=0).
force: The command is executed without interactive operation with the user.
(3) Usage example
Example:When you start MDC to the logical drive#0.
# start raid mdc SB 0-0 target=0
(4) Message
The following table lists the messages which are displayed in this CLI.
For details of the messages, see the PRIMEQUEST 2000 Series Message Reference (CA92344-0540).
The command is executed successfully.
The operation is canceled
Too much arguments argc=%d.
Too few arguments argc=%d.
The specified parameter is invalid. %s
The specified controller is not found.
Internal error [%d:%d].
The operation is failed. %s
Unable to execute the command because the %s is under maintenance.
Unable to process raid operation because you have not authority to access to the system assigned to the raid
controller.
Unable to process raid operation because you have not authority to access to the Partition#%d assigned to the
raid controller.