MMB Web-UI (Web User Interface) Operations
1.2 [System] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E
117
CA92344-0539-04
[SB#x Status Clear] Window
When the [Status Clear] button on the [SB#x] window is clicked, whether to clear the error status of the
component can be specified.
The error status of the component in which an abnormality is detected on the SB is canceled, the relevant
component can be specified so that it can be used again at the time of next reboot. If error is detected again
at the time of re-boot, then the error status of that such component is registered again.
When the check box of "Clear Status of common parts" is checked, things except CPU/DIMM (Chipset
system) are cleared.
FIGURE 1.29 [SB#x Status Clear] Window (Message Display)
(1) Menu Operation
[System]
– [SB] – [SB#x] – [Status Clear] button
(2) Window Operations
1.
Specify as given below to clear the component.
·
Select [Clear All Status] to clear all the components.
·
Select [Clear Specified Status] to individually clear the error status of the components, and check
the [Status Clear] checkbox of the status of the components to be cleared.
·
Check the [Clear Status of common parts] check box to clear the common parts.
2.
Click the [Apply] button.
The specified components are set to clear.