MMB Web-UI (Web User Interface) Operations
1.7 [System] Menu for PRIMEQUEST 2800B2/2800B
300
CA92344-0539-04
TABLE 1.148 Display Items and Set Items of [Power Control] Window
Items
Description
Status
Displays the Status of the System.
Normal
Warning
Error
Power Status
Displays the Power Status of the System.
On
Standby
System Progress
The status of the partition progress is displayed.
Power Off: The partition power is off.
Power On In Progress: Partition power on is in process.
Reset: The status of the partition from the beginning of reset till the
completion of the operating system boot.
EFI: The UEFI menu screen is displayed.
Boot: Operating system is being booted.
Operating system Running: Operating system running state
Operating system Shutdown: Operating system shutting down.
Panic: Panic (Only in RHEL)
Power Off In Progress: Partition power off is in process.
Fatal: Stopped.
Dumping: The dumping is being output.
Halt: Halting.
Remarks
When SVAS (Server View Agentless Service) is not installed to system,
the display is not switched over in ‘Operating system Running’ even if
Operating system is working.
Moreover, for ‘Operating system shutdown’, ‘Panic’ commanded by
SVAS if SVAS (Server View Agentless Service) is not installed, there is
no display.
When REMCS Option is installed on Partition of RHEL, "Panic" is
displayed. It is not displayed in Windows.
SVAS : Specifies the piece of software running on the OS in managed
nodes to help BMC with management. Unless SVAgent, it does not
provide management interface to the outside.