MMB Web-UI (Web User Interface) Operations
1.2 [System] Menu for PRIMEQUEST 2400E2/2800E2/2400E/2800E
143
CA92344-0539-04
Items
Description
Status
The state of a physical drive is displayed.
·
Operational
·
Available
·
Failed
·
Hot Spare
·
Rebuilding
·
SMART err
·
Shielded
·
Bad Block
·
Not-present
Vendor
The vendor name of a physical drive is displayed.
Model
The model name of a physical drive is displayed.
Capacity
The capacity of a physical drive is displayed.
Temperature
The temperature of a physical drive is displayed.
Logical Drives
Sensor#
The sensor number of a logical drive is displayed.
Status
The state of a logical drive is displayed.
Raid Level
The RAID level of a logical drive is displayed.
Physical Drives
assignment
The slot number of a physical drive that composes a logical drive is displayed.
Missing drives count
The number of physical drives missed to compose a logical drive at the RAID level
is displayed.
RAID Action Progress
Drive Type
The drive type that the RAID action is executed is displayed.
·
Physical : Hardware RAID
·
Logical : Software RAID
Slot#/Sensor#
Slot# from which the RAID action is executed is shown when Drive Type is
Physical, and Sensor# from which the RAID action is executed is shown when
Drive Type is Logical.
Action
The RAID action under execution is displayed.
·
Rebuilding : It is shown for a physical drive to execute the rebuild of the RAID
drive.
·
Copyback Running : It is shown for a physical drive to execute the copy
backing
·
MDC Running : It is shown for a logical drive to execute MDC(Make Data
Consistent).
Progress(%)
The progress rate of the RAID action under execution is displayed by the
percentage.
Estimated time
remaining (hh:mm:ss)
The remainder time that will be expected by the time the RAID action under
execution is completed is displayed.
Expander
Expander#
The number of the expander is displayed.
Status
Displays the status of the Expander.
OK
Warning
Failed
Not-Present
PSU
PSU
#
The number of the exp PSU ander is displayed.