SVmco User Guidel
740
SV RAID:%2 Device error (Multiple failure on disk detected)
Meaning:
More than one HDD failed.
%2: Device name
Corrective action:
If the target logical drive is degraded, replace the HDD, and perform a rebuild.
If the target logical drive is offline, take corrective action according to the multi-
dead recovery procedure.
Severity:
Error
Action:
(R/M/T/S)
18583
SV RAID:%2 Device error (Disk failed since it never entered ready state)
Meaning:
The hard disk did not enter the ready state.
%2: Device name
Corrective action:
If the hard disk is faulty, replace it.
Severity: