SVmco User Guidel
596
%ser: (Example) 01234567
Corrective action:
Identify the type of the target unit. Then, check the sense key (extended sense)
in the original message to determine the corrective action.
1 (Recovered Error): If it is a removable device, perform cleaning.
2 (Not Ready): If it is non-removable, replace the device.
3 (Medium Error): If it is a disk, replace the device. If it has removable media,
perform cleaning and replace the media.
4 (Hard Error): Replace the device.
5 (Illegal Request): Examine the software.
6 (Unit Attention): This is notification information from various devices. (e.g.,
reset status, degradation)
7 (Data Protect): Check the Write Protect status.
8 (Blank Check): Check tape and other operations.
b (Aborted Command): Investigate problems in the SCSI bus and Fibre Channel
transmission paths.
Severity:
Warning
Action:
(R/M/T/S)
14062
scsi: Software error (Incorrect number of segments)