SVmco User Guide
711
18536
SV RAID:%2 Adapter error (Previous configuration completely missing at
boot) vendor-id=1000/1734 device-id=%d revision=%r
Meaning:
The configuration could not be found at startup.
%2: Device name
%d: (Example) 0060/10F9 (device-id/sub device-id)
%r: Numerical value (1 to 3 digits)
Corrective action:
Power off the system. Then, confirm that the HDD, cable, power supply, and
other components are correctly connected. If the error recurs, replace the
possibly faulty component of the SAS interface system.
Severity:
Warning
Action:
(R/M/T/S)
18537
SV RAID:%2 Device error (Logical drive partially degraded)
Meaning:
The logical drive entered the degraded state.
%2: Device name