SVmco User Guide
151
6.
After replacing the hard disk, confirm that hard disk replacement was
completed properly, by using the following steps depending on whether the
disk is a spare disk.
o
If not set as a spare disk:
ServerView RAID Manager automatically performs a rebuild. Then,
the Alarm LED of the hard disk starts blinking.
Wait until the rebuild is complete in the ServerView RAID Manager
window. Confirm that [Status] for the hard disk is [Operational].
o
If set as a spare disk:
The replacement hard disk automatically becomes a spare disk.
Then, the Alarm LED of the hard disk goes out.
In the [ServerView RAID Manager] window, confirm that [Status] for
the hard disk is [Global Hot Spare] or [Dedicated Hot Spare]. After
the rebuild is complete, a copyback operation may be performed.
7.
Exit ServerView RAID Manager.
4.3.2.
Hard disk preventive replacement
This section describes the workflow for preventive replacement of a hard disk S.M.A.R.T
predicted to fail.
For the RAID 0 configuration (cold-partition replacement)
To replace a hard disk in the RAID 0 configuration, apply cold-partition
maintenance.
The workflow is described below.