SVmco User Guide
141
o
Stop the disk rotation. The Fault LED (amber) goes on.
o
Instruct the operating system to remove the target disk.
# /opt/fujitsu/SVmco/bin/diskctrl -e /dev/sdc
4.
Remove the hard disk at the location indicated by the Fault LED (amber)
that is on. When an internal hard disk is removed, the Fault LED behind its
slot goes on. The Fault LED goes on or blinks until it is turned off by the
disk management command or the partition is powered off or rebooted.
Note
If there is an SSD, removing the SSD may output the W13139
message from SVagent to the system event log.
To turn off the Fault LED with the disk management command, perform
the following operations.
1) Display the status by executing the disk management command, and
confirm the location with the Fault LED that is on.
# /opt/fujitsu/SVmco/bin/diskctrl -l ioc0
0 /dev/sda
Fault LED-Off
1 /dev/sdb
Fault LED-Off
2 none
Fault LED-On
3 /dev/sdd
Fault LED-Off