STEP 2: Selecting the function number and setting value
1. Press the TEMP./SELECT ( ) ( ) buttons to select the function
number. To switch between the left and right digits, press the MODE
button.
2. Press the FAN SPEED button to proceed the setting value. To re-
turn the function number selection, press the FAN SPEED button
again.
3. Press the TEMP./SELECT ( ) ( ) buttons to select the setting val-
ue. To switch between the left and right digits, press the MODE but-
ton.
4. Press the TIMER button, and
/
(START/STOP) button, in the or-
der listed to confirm the settings.
5. Press the RESET button to cancel the function setting mode.
6. After completing the function setting, be sure to disconnect the pow-
er supply and then reconnect it.
Function number
Setting value
CAUTION
After disconnecting the power supply, wait 30 seconds or more before reconnecting it. The function
setting will not become active unless the power supply is disconnected and then reconnected.