Check point 3-1. Turn on the power again of air conditioner.
If check point 1 to 2 do not improve the symptom, turn on the power of the air conditioner again and
wait for 60 seconds.
-> When the flashing pattern of the LED 2 (orange) is on, go to
-> When the flashing pattern of the LED 2 (orange) is flashing fast, go to
.
↓
Check point 3-2. Check the connection.
•
Check any loose or removed connection of between the wireless LAN adapter PCB and con-
troller PCB.
-> If there is abnormal condition, correct it.
•
Check the connection condition on the controller PCB.
-> If there is loose connector, open cable or mis-wiring, correct it.
↓
Check point 4. Replace wireless LAN adapter.
If check point 2 to 3 do not improve the symptom, replace the wireless LAN adapter and cancel the
registration of air conditioner on the mobile app.
After replacing the adapter, perform the pairing on the mobile app.
For the method of the mobile app, refer to
↓
Check point 5. Replace controller PCB
If check point 4 do not improve the symptom, replace the controller PCB.
↓
End
4-4. E: 18. Communication error
- (03-40) -
4. Troubleshooting with error code (For wireless LAN adapter)
TROUBLESHOOTING
TROUBLESHOOTING
Summary of Contents for General ASHG07KPCE
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Page 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Page 34: ......
Page 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Page 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...