![Fujitsu General ASHG07KPCE Service Manual Download Page 7](http://html.mh-extra.com/html/fujitsu/general-ashg07kpce/general-ashg07kpce_service-manual_2343874007.webp)
1. Specifications
1-1. Indoor unit
Type
Wall mounted
Inverter heat pump
Model name
ASHG07KPCE
ASHG09KPCE
ASHG12KPCE
Power supply
230 V ~ 50 Hz
Power supply intake
Outdoor unit
Available voltage range
198—264 V
Capacity
Cooling
Rated
kW
2.00
2.50
3.40
Btu/h
6,800
8,500
11,600
Min.—Max.
kW
0.9—2.8
0.9—3.0
0.9—3.7
Btu/h
3,100—9,600
3,100—10,200
3,100—12,600
Heating
Rated
kW
2.50
2.80
3.80
Btu/h
8,500
9,500
13,000
Min.—Max.
kW
0.9—3.4
0.9—3.8
0.9—4.80
Btu/h
3,100—11,600
3,100—12,900
3,100—16,400
Input power
Cooling
Rated
kW
0.48
0.71
1.00
Min.—Max.
0.25—1.03
0.25—1.05
0.25—1.14
Heating
Rated
0.63
0.79
1.14
Min.—Max.
0.25—1.39
0.25—1.39
0.25—1.60
Fan
HIGH
W
21.5
26.9
MED
12.5
14.5
LOW
6.3
7.1
QUIET
3.0
3.0
Current
Cooling
Rated
A
2.7
3.5
4.7
Heating
3.2
3.8
5.6
EER
Cooling
kW/kW
4.17
3.52
3.40
COP
Heating
3.97
3.54
3.33
Sensible capacity
Cooling
kW
1.9
2.1
2.6
Power factor
Cooling
%
77
87
92
Heating
85
90
89
Moisture removal
L/h (pints/h)
1.0 (1.80)
1.3 (2.30)
1.8 (3.20)
Maximum operating current *
1
Cooling
A
6.5
Heating
9.0
Fan
Airflow rate
Cooling
HIGH
m
3
/h
580
630
MED
460
490
LOW
340
360
QUIET
240
240
Heating
HIGH
580
630
MED
460
490
LOW
380
380
QUIET
260
260
Type × Q'ty
Crossflow fan × 1
Motor output
W
27
Sound pressure level *
2
Cooling
HIGH
dB (A)
45
46
MED
38
40
LOW
31
33
QUIET
22
22
Heating
HIGH
45
46
MED
40
40
LOW
36
35
QUIET
26
27
Heat exchanger type
Dimensions (H × W × D)
mm
210 × 600 × 26.6
Fin pitch
1.3
Rows × Stages
2 × 10
Pipe type
Copper tube
Fin type
Aluminum
Enclosure
Material
Polystyrene
Color
White
Approximate color of Munsell N 9.25/
Dimensions
(H × W × D)
Net
mm
270 × 784 × 224
Gross
279 × 864 × 334
Weight
Net
kg
8.0
Gross
11.0
Connection pipe
Size
Liquid
mm (in)
Ø6.35 (Ø1/4)
Gas
Ø9.52 (Ø3/8)
Method
Flare
Drain hose
Material
PP+HDPE
Tip diameter
mm
Ø13.8 (I.D.), Ø15 to Ø16.8 (O.D.)
Operation range
Cooling
°C
18 to 32
%RH
80 or less
Heating
°C
16 to 30
Remote controller type
Wireless (Option: Mobile app*
3
[FGLair
™
])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 27 °CDB/19 °CWB, and outdoor temperature of 35 °CDB/24 °CWB.
– Heating: Indoor temperature of 20 °CDB/15 °CWB, and outdoor temperature of 7 °CDB/6 °CWB.
– Pipe length: 5 m, Height difference: 0 m. (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *1: Maximum current is maximum value when operated within the operation range.
• *2: Sound pressure level:
–
Measured values in manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *3: Available on Google Play
™
store or on App Store
®
. Optional WLAN Adapter is also required. For details, refer to the setting manual.
1-1. Indoor unit
- (01-1) -
1. Specifications
GENERAL
INFORMATION
GENERAL
INFORMATION
Summary of Contents for General ASHG07KPCE
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Page 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Page 34: ......
Page 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Page 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...