Sleep timer
If the sleep timer is set, the room temperature is monitored and the operation is stopped auto-
matically. If the operation mode or the set temperature is change after the sleep timer is set, the
operation is continued according to the changed setting of the sleep timer from that time on.
• In the cooling operation mode
When the sleep timer is set, the setting temperature is increased 1°C. It increases the setting
temperature another 1°C after 1 hour. After that, the setting temperature is not changed and
the operation is stopped at the setting time.
Set temperature rises
Ts: Set temperature
Stop of operation
Ts
+2°C
Set
60 min
+1°C
• In the heating operation mode
When the sleep timer is set, the setting temperature is decreased 1°C. It decreases the setting
temperature another 1°C every 30 minutes. Upon lowering 4°C, the setting temperature is not
changed and the operation is stopped at the setting time.
Set
Ts
-2°C
-1°C
-3°C
-4°C
Ts: Set temperature
30 min
30 min
30 min
Stop of operation
Set temperature rises
5-1. Wireless remote control
- (04-17) -
5. Timer operation control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS
Summary of Contents for General ASHG07KPCE
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 12 16 SR_CH01_AS059EG_01 ...
Page 13: ...2 TECHNICAL DATA AND PARTS LIST 2022 07 07 SR_CH02_AS059EG_02 ...
Page 31: ...3 TROUBLESHOOTING 2022 07 07 SR_CH03_AS059EG_02 ...
Page 34: ......
Page 92: ...6 2 Outdoor unit 03 58 6 Thermistor resistance values TROUBLESHOOTING TROUBLESHOOTING ...
Page 93: ...4 CONTROL AND FUNCTIONS 2022 07 07 SR_CH04_AS059EG_02 ...
Page 125: ...5 FILED WORKING 2022 07 07 SR_CH05_AS059EG_02 ...