4-5. E: 18.X. Wireless LAN adapter non-energized
Indicator
Indoor unit
Operation indicator
1 time flash
Timer indicator
8 time flash
Economy indicator
Continuous flash
Error code
E: 18
→ireless LAN
adapter
LED1 (green)
Off
LED2 (orange)
Off
Detective actuator Indoor unit controller PCB
→hen the voltage (DC 12 V) does not output from the
controller PCB.
→ireless LAN adapter PCB
Forecast of cause
Indoor unit controller PCB failure
→ireless LAN adapter PCB failure
→iring connection failure
Check point 1. Check the connection.
•
Check any loose or removed connection of between the wireless LAN adapter PCB and con-
troller PCB.
-> If there is abnormal condition, correct it.
•
Check the connection condition on the controller PCB.
-> If there is loose connector, open cable or mis-wiring, correct it.
Check point 2. Check the wireless LAN adapter PCB and the controller PCB
Check voltage at CN6 (terminal 1—2) of main PCB.
(Power supply to remote controller)
•
If it is DC 0 V, controller PCB is failure.
-> Replace controller PCB.
•
If it is DC 12 V, wireless LAN adapter PCB is failure.
-> Replace the wireless LAN adapter and cancel the registration of air condi-
tioner on the mobile app.
After replacing the adapter, perform the pairing on the mobile app.
For the method of the mobile app, refer to
End
4-5. E: 18.↓. →ireless LAN adapter non-energized
- (03-73) -
4. Troubleshooting with error code (For wireless LAN adapter)
TR
O
U
B
LESH
O
O
TI
N
G
TR
O
U
B
LESH
O
O
TI
N
G
Summary of Contents for AOUH18LMAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Page 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Page 42: ......
Page 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Page 138: ......
Page 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...