Available Sensor ID
Sensor ID
Item
Unit
Remarks
01
089
Base heater output On/Off
08: On/Off
0: Off, 1: On
01
090
Belt heater output On/Off
08: On/Off
0: Off, 1: On
01
100
Operating current
09: A
01
110
Outdoor unit total power-on hours
11: h
01
111
Compressor total heating operation
hours
11: h
01
112
Compressor total cooling operation
hours
11: h
01
113
Compressor total operation hours
11: h
01
114
Outdoor unit fan 1 total operation
hours
11: h
01
115
Outdoor unit fan 2 total operating
hours
11: h
01
145
Outdoor low noise input (External
input)
00: —
0: Off, 1: On
01
146
Outdoor peak cut (External input)
00: —
0: Off
1: Mode 4 (100%)
2: Mode 3 (75%)
3: Mode 2 (50%)
4: Mode 1 (Forced thermostat off)
01
147
Demand response (External input)
00: —
0: Normal, 1: DRM1, 2: DRM2, 3:
DRM3
01
148
Switching cooling and heating mode
(External input)
00: —
0: Cooling, 1: Heating
01
149
Emergency stop (External input)
00: —
0: Off, 1: On
7-14. Unit status monitoring and the detected value indication
- (04-30) -
7. Various control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for AOUH18LMAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Page 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Page 42: ......
Page 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Page 138: ......
Page 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...