8-7. High temperature and high pressure release control
The compressor is controlled as follows.
¢
Models: AOUH09LUAS1, AOUH12LUAS1, and AOUH18LUAS1
•
Cooling mode
Indoor unit heat exchanger
temperature rises
Indoor unit heat exchanger
temperature drops
Stable zone
AB
BC
CD
DE
Zone A
Zone B
Zone C
Zone D
Zone E
AB: 141.8°F (61°C)
BC: 140.0°F (60°C)
CD: 138.2°F (59°C)
DE: 129.2°F (54°C)
Zone
Operation
Zone A
Compressor is stopped.
Zone B
The compressor frequency is decreased.
-30 rps/30 sec.
Zone C
-5 rps/60 sec.
Zone D
The protection is released and the operation is returned to normal mode.
Zone E
•
Heating mode
Indoor unit heat exchanger
temperature rises
Indoor unit heat exchanger
temperature drops
Stable zone
AB
BC
CD
DE
Zone A
Zone B
Zone C
Zone D
Zone E
AB: 141.8°F (61°C)
BC: 131.0°F (55°C)
CD: 127.4°F (53°C)
DE: 122.0°F (50°C)
Zone
Operation
Zone A
Compressor is stopped.
Zone B
The compressor frequency is decreased.
-25 rps/120 sec.
Zone C
-3 rps/60 sec.
Zone D
The protection is released and the operation is returned to normal mode.
Zone E
8-7. High temperature and high pressure release control
- (04-35) -
8. Various protections
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for ACUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Page 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Page 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Page 48: ......
Page 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Page 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...