14) Operating temperature switching of external heaters
Sets the temperature conditions when the external heater is ON.
For details, refer to “External heater output” in Chapter 0-1. "Details of function" on page 1.
Function
number
Setting
value
Setting description
Factory
setting
Setting value of function 61:
00
01 to 09
Heater: On
Heater: Off
Heater: On
Heater: Off
62
00
-5.4 °F (-3 °C)
-1.8 °F (-1 °C)
-0.9 °F (-0.5 °C)
0.9 °F (0.5 °C)
♦
01
-3.6 °F (-2 °C)
-1.8 °F (-1 °C)
-1.8 °F (-1 °C)
0.9 °F (0.5 °C)
02
-3.6 °F (-2 °C)
-1.8 °F (-1 °C)
-3.6 °F (-2 °C)
0.9 °F (0.5 °C)
03
-5.4 °F (-3 °C)
-1.8 °F (-1 °C)
-5.4 °F (-3 °C)
0.9 °F (0.5 °C)
04
-7.2 °F (-4 °C)
-1.8 °F (-1 °C)
-7.2 °F (-4 °C)
0.9 °F (0.5 °C)
05
-9.0 °F (-5 °C)
-1.8 °F (-1 °C)
-9.0 °F (-5 °C)
0.9 °F (0.5 °C)
06
-5.4 °F (-3 °C)
-0.9 °F (-0.5 °C) -0.9 °F (-0.5 °C)
0 °F (0 °C)
07
-3.6 °F (-2 °C)
-0.9 °F (-0.5 °C)
-1.8 °F (-1 °C)
0 °F (0 °C)
08
-3.6 °F (-2 °C)
-0.9 °F (-0.5 °C)
-3.6 °F (-2 °C)
0 °F (0 °C)
09
-5.4 °F (-3 °C)
-0.9 °F (-0.5 °C)
-5.4 °F (-3 °C)
0 °F (0 °C)
10
-7.2 °F (-4 °C)
-0.9 °F (-0.5 °C)
-7.2 °F (-4 °C)
0 °F (0 °C)
11
-9.0 °F (-5 °C)
-0.9 °F (-0.5 °C)
-9.0 °F (-5 °C)
0 °F (0 °C)
12
-5.4 °F (-3 °C)
0 °F (0 °C)
-0.9 °F (-0.5 °C) -0.9 °F (-0.5 °C)
13
-3.6 °F (-2 °C)
0 °F (0 °C)
-1.8 °F (-1 °C)
-0.9 °F (-0.5 °C)
14
-3.6 °F (-2 °C)
0 °F (0 °C)
-3.6 °F (-2 °C)
-0.9 °F (-0.5 °C)
15
-5.4 °F (-3 °C)
0 °F (0 °C)
-5.4 °F (-3 °C)
-0.9 °F (-0.5 °C)
16
-7.2 °F (-4 °C)
0 °F (0 °C)
-7.2 °F (-4 °C)
-0.9 °F (-0.5 °C)
17
-9.0 °F (-5 °C)
0 °F (0 °C)
-9.0 °F (-5 °C)
-0.9 °F (-0.5 °C)
15) Outdoor temperature zone boundary temperature A
Setting required if changing of the outdoor temperature setting for heat pump prohibition zone is re-
quired when auxiliary heater control by outdoor temperature 1 and 2 are performed on the indoor
unit. For details, refer to “External heater output” in Chapter 0-1. "Details of function" on page 1.
Function number
Setting value
Setting description
Factory setting
66
00
-4.0 °F (-20 °C)
♦
01
-0.4 °F (-18 °C)
02
3.2 °F (-16 °C)
03
6.8 °F (-14 °C)
04
10.4 °F (-12 °C)
05
14.0°F (-10 °C)
06
17.6 °F (-8 °C)
07
21.2 °F (-6 °C)
08
24.8 °F (-4 °C)
1-2. Function settings by using remote controller
- (05-7) -
1. Function settings
FI
EL
D
W
O
R
K
IN
G
FI
EL
D
W
O
R
K
IN
G
Summary of Contents for ACUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Page 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Page 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Page 48: ......
Page 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Page 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...