3-2. Outdoor fan control
¢
Outdoor fan motor
This outdoor unit has a DC fan motor. (Control method is different between AC and DC motors.)
¢
Fan speed
Model: AOUH09LUAS1
Fan speed is defined by outdoor temperature and compressor frequency.
•
Outside air temperature zone selection
Outside air
temperature rises
Z zone
Y zone
F zone
G zone
Outside air
temperature drops
H zone
53.6°F
(
12
°C)
35.6°F
(
2
°C)
50.0
°F
(
10
°C)
32.0
°F
(
0
°C)
17.6°F
(
-8
°C)
14.0°F
(
-10
°C)
69.8°F
(
21
°C)
66.2
°F
(
19
°C)
Unit: rpm
Fan step
Cooling
Heating
Dry
Cooling or dry at low outdoor temp.
Y zone
Y zone
Z zone
F zone
G zone
H zone
S-HIGH2
—
1,120
—
—
—
—
—
S-HIGH1
990
1,120
—
—
—
—
—
HIGH
990
1,120
—
—
—
—
—
10
—
1,120
—
—
—
—
—
9
990
1,120
990
390
320
240
240
8
940
1,120
940
390
320
240
240
7
810
940
810
390
320
240
240
6
810
810
810
300
240
200
200
5
810
690
810
250
240
200
200
4
790
630
790
250
240
200
200
3
710
570
710
250
240
200
200
2
660
570
660
250
240
200
200
1
620
570
620
250
240
200
200
NOTE:
After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 1,120 rpm
3-2. Outdoor fan control
- (04-13) -
3. Fan control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for ACUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Page 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Page 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Page 48: ......
Page 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Page 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...