Models: AOUH12LUAS1 and AOUH18LUAS1
•
1st time defrosting after starting operation
Compressor integrating
operation time
Less than 17 min.
17 to 57 min.
More than 57 min.
Condition
Does not operate
Tn ≤ 15.8°F (-9°C) and
Tn-Ta ≥ 9.0°F (5°C)
Tn ≤ 23.0°F (-5°C)
•
2nd time and after
Compressor integrating
operation time
Less than 40 min.
More than 40 min.
Condition
Does not operate
Tn-Tn10 < -9.0°F (-5°C) (Tn ≤ 21.2°F [-6°C])
Tn-Tnb < -3.6°F (-2°C) (Tn ≤ 21.2°F [-6°C])
Tn ≤ -4.0°F (-20°C) (Ta ≥ 14.0°F [-10°C])
Tn ≤ 19.4°F (-7°C) or Tn ≤ -13.0°F (-25°C) (Ta <
14.0°F [-10°C])
•
Integrating defrost (Constant monitoring)
Compressor integrating
operation time
More than 240 min. (For
long continuous
operation)
More than 213 min. (For
long continuous
operation
Less than 10 min.* (For
intermittent operation)
Condition
Tn ≤ 26.6°F (-3°C)
Tn ≤ 23.0°F (-5°C)
Count of the compressor
off: 40 times
*: If the compressor continuous operation time is less than 10 minutes, the number of the
compressor off is counted. If any defrost operated, the compressor off count is cleared.
•
Release condition
The defrost operation is released when either one of the conditions below is satisfied.
Outdoor unit heat exchanger temperature
(after 1 minute or later since compressor start)
09 model
60.8°F (16°C) or more
12/18 model
55.4°F (13°C) or more
Compressor operation time
15 minutes
6-1. Defrost operation in heating operation stopped
If the outdoor unit is frosted when stopping the heating operation, it stops after performing the auto-
matic defrosting operation.
In this time, if the indoor unit operation lamp flashes slowly (6 sec on/2 sec off), the outdoor unit al-
low the heat exchanger to defrost, and then stop.
•
Triggering condition
→hen all of the following conditions are satisfied in heating operation
– Compressor operation integrating time: 30 minutes or more
– Compressor continuous operation time: 10 minutes or more
– Outdoor unit heat exchanger temperature: 24.8°F (-4°C) or less
•
Release condition
The defrost operation is released when either one of the conditions below is satisfied.
Outdoor unit heat exchanger temperature
(after 1 minute or later since compressor start)
09 model
60.8°F (16°C) or more
12/18 model
55.4°F (13°C) or more
Compressor operation time
15 minutes
6-1. Defrost operation in heating operation stopped
- (04-24) -
6. Defrost operation control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Summary of Contents for ACUH09LUAS1
Page 4: ......
Page 5: ...1 GENERAL INFORMATION 2021 04 02 SR_CH01_AU021EF_01 ...
Page 14: ...2 2 Outdoor unit 01 8 2 Dimensions GENERAL INFORMATION GENERAL INFORMATION ...
Page 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 04 02 SR_CH02_AU021EF_01 ...
Page 45: ...3 TROUBLESHOOTING 2021 04 26 SR_CH03_AU021EF_01 ...
Page 48: ......
Page 105: ...4 CONTROL AND FUNCTIONS 2021 04 26 SR_CH04_AU021EF_01 ...
Page 143: ...5 FILED WORKING 2021 04 26 SR_CH05_AU021EF_01 ...