199
PRIMERGY RX600 S4 User's Guide
Server Management Tools error messages
The following error messages may appear while executing Server Management Tools. In such cases,
perform the appropriate resolutions. If messages other than the following are displayed, contact an office
listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
PSU Red
The power supply redundancy has been lost. Replace the relevant
PSU. If the message still appears after the replacement, Power BP
or the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
table: List of Server Management Tools error messages
Message
Description
Write protect error writing drive A.
Abort, Retry, Fail?
The inserted floppy disk is write-protected. Disable the
write-protect, and then press the [R] key.
Not ready writing drive A.
Abort, Retry, Fail?
The floppy disk is not inserted. Insert the proper floppy
disk ("Server Management Tools" disk), and then press
the [R] key.
ERROR: Fail to create data file.
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is write-protected. Disable the
write-protect and retry.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" disk again. If this
occurs while recovering the BIOS information,
configure the information using BIOS Setup Utility.
Then store the BIOS information.
ERROR: Fail to write 1st CMOS data into data file. nn
ERROR: Fail to write 2nd CMOS data into data file. nn
ERROR: Fail to write ESCD data into the data file. nn
ERROR: Fail to write SEEPROM data into the data
file. nn
ERROR: Fail to open data file.
The file to recover the BIOS information does not exist
on this floppy disk. Insert the floppy disk on which the
BIOS information was stored, and then retry.
ERROR: Fail to write 1st CMOS data into system. nn
The following factors may be possibly root causes.
Check the floppy disk condition again.
• The floppy disk is not inserted. Insert the proper
floppy disk, and then retry.
• This is a different model or an unsupported version
of BIOS information. Insert the proper floppy disk,
and then retry.
• The floppy disk contains improper data. Create
"Server Management Tools" disk again. If this
occurs while recovering BIOS information,
configure the information using BIOS Setup Utility.
Then store the BIOS information.
ERROR: Fail to write 2nd CMOS data into system file.
nn
ERROR: Fail to write ESCD data into system file. nn
ERROR: Fail to write SEEPROM data into system. nn
Other messages
Contact an office listed in the "Contact Information" of
"Start Guide".
table: List of POST error messages
Message
Description
Summary of Contents for 1PRIMERGY RX600 S4
Page 12: ...12 ...
Page 42: ...42 Chapter 1 Overview ...
Page 114: ...114 Chapter 5 High Reliability Tools ...
Page 180: ...180 Chapter 7 Configuring Hardware and Utilities ...