198
Chapter 8 Operation and Maintenance
iRMC reports sensor status: CRITICAL
Voltages
It indicates a voltage error/warning. Turn off the server, and
unplug the power cable from the outlet. Then, reconnect the
power cable, and turn on the server. If the message still appears,
check the error log and replace the relevant parts. If the message
still appears thereafter, the baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
Voltages
iRMC reports sensor status: CRITICAL
Battery
It indicates a voltage error/warning of a battery. Turn off the
server, and unplug the power cable from the outlet. Then,
reconnect the power cable, and turn on the server. If the message
still appears, the battery or baseboard must be replaced. Contact
an office listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
Battery
iRMC reports sensor status: CRITICAL
FAN* SYS
(The mark, *, indicates the number, 1 to 4)
It indicates a system fan error/warning. Check whether there are
any obstacles interfering the fan rotation. If the message appears
although there is no interference, the system fan or baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
iRMC reports sensor status: WARNING
FAN* SYS
(The mark, *, indicates the number, 1 to 4)
iRMC reports sensor status: CRITICAL
FAN* MEM
(The mark, *, indicates the number, 1 to 4)
It indicates a PSU fan error. Check whether there are any
obstacles interfering the fan rotation. If the message appears
although there is no interference, the PSU fan, Power BP, or
baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
FAN* MEM
(The mark, *, indicates the number, 1 to 4)
iRMC reports sensor status: CRITICAL
DIMM-**
(The mark, **, indicates the installation
location)
It indicates a memory module error. Replace the relevant memory
module. If the message still appears after the replacement, the
memory board or baseboard must be replaced. Contact an office
listed in the "Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING
DIMM-**
(The mark, **, indicates the installation
location)
iRMC reports sensor status: CRITICAL PCI
Slot*
(The mark, *, indicates the number, 1 to 7)
It indicates an expansion card slot error. Replace the relevant
expansion card. If the message still appears after the replacement,
the baseboard must be replaced. Contact an office listed in the
"Contact Information" of "Start Guide".
iRMC reports sensor status: WARNING PCI
Slot*
(The mark, *, indicates the number, 1 to 7)
iRMC reports sensor status: CRITICAL
CPU*
(The mark, *, indicates the number, 1 to 4)
It indicates a CPU error. Replace the relevant CPU. If the
message still appears after the replacement, the baseboard must be
replaced. Contact an office listed in the "Contact Information" of
"Start Guide".
iRMC reports sensor status: WARNING
CPU*
(The mark, *, indicates the number, 1 to 4)
iRMC reports sensor status: CRITICAL
PSU*
(The mark, *, indicates the number, 1 or 2)
It indicates a PSU error. Replace the relevant PSU. If the message
still appears after the replacement, the Power BP or baseboard
must be replaced. Contact an office listed in the "Contact
Information" of "Start Guide".
iRMC reports sensor status: WARNING
PSU*
(The mark, *, indicates the number, 1 or 2)
table: List of POST error messages
Message
Description
Summary of Contents for 1PRIMERGY RX600 S4
Page 12: ...12 ...
Page 42: ...42 Chapter 1 Overview ...
Page 114: ...114 Chapter 5 High Reliability Tools ...
Page 180: ...180 Chapter 7 Configuring Hardware and Utilities ...