61
Maintenance Menu
9. Arc Discharge
The arc discharge in the splicer can be manually operated. During splicing, the arc
discharge can also be operated by calling this menu in the [PAUSE] or [FINISH] state.
(1) Pressing , arc discharge
is performed.
10. Maintenance Info
The following information is displayed.
Parameter
Description
Serial Num.
Displays the serial number of the splicer.
ROM Version
Displays the version number of the software.
Arc Count
Displays the number of arc discharges since electrode
replacement. Performing the function [Replace Electrodes] or
[Arc Count Clear] resets this parameter to zero.
Total Count
Displays the total number of arc discharges.
Last Maintenance Displays the date of last maintenance.
Next Maintenance Displays the scheduled date of next
maintenance.
To enter the date, refer to
[Other Option] (Page 55).