45
Splice Menu
Parameter
Description
Ignore Splice Error
Offset
Gap
Cleave
Setting to “Disable” prevents the splicer from continuing a
splice even if the message “Offset Error”, “Gap Error”, “Cleave
Angle Error” is disregarded.
Loss
Bubble
Fat
Thin
Setting to “Disable” prevents the splicer from normally
finishing its operation even if the message “Loss Error,”
“Bubble Error,” “Fat Error” or “Thin Error” is disregarded.
Arc Compensation
Arc
Compensation
Temperature
Setting to “OFF” turns off arc power compensation due to
pressure and temperature changes.
Fiber Image on Screen
Auto Fiber
Forward
If “Auto Fiber Forward” is set to “ON”, fibers are automatically
moved closer to gapset as soon as wind protector is closed.
Cleave Shape
Error
Error message is displayed if the cleaved end face of either left
or right fiber exceeds the selected threshold (cleave shape).
Max. Number of
Rearcs
The re-arcing process sometimes improves the splice loss, but
sometimes worsens it. Re-arcing decreases the splice strength.
With this function, it is possible to limit the number of re-arcs or
to disable re-arc discharge.