35
Splice Menu
AUTO mode
Below is a list of Splicing parameters for AUTO modes. The AUTO mode consists of
[AUTO], [SM AUTO], [NZ AUTO], [DS AUTO], and [MM AUTO].
Only a limited number of parameters listed below are displayed for these modes to
simplify the operation. Additional hidden parameters are automatically selected.
Parameter
Description
Fiber Type
List of splice modes stored in database is displayed. A selected
splice mode stored in the database area is copied to a selected splice
mode in the user-programmable area.
Mode Title1
Title for a splice mode expressed in up to 14 characters.
Title1 is displayed at the left corner while splicing.
Mode Title2
Detailed explanation for a splice mode expressed in up to 14
characters. Title2 is displayed at the [Splice Mode Select] menu.
Offset Limit
An error message is displayed if the fiber offset exceeds the selected
threshold (offset limit).
Cleave Limit An error message is displayed if the cleave angle of either the left or
right fiber ends exceeds the selected threshold (cleave limit).
Gap Dif. Limit An error message is displayed if the gap between the left and right
fiber ends exceeds the selected threshold (gap limit).
Loss Limit
An error message is displayed if the estimated splice loss exceeds
selected threshold (loss limit).
Cleaning Arc
A cleaning arc burns out micro dust on the surface of the fiber with
an arc discharge for a short period of time. The duration of the
cleaning arc can be changed by this parameter.
Rearc Time
Splice loss may be improved by an additional “rearc” discharge in
some cases. The duration of this additional arc can be changed by
this parameter.
Arc Power
Arc Time
These parameters cannot be changed. The splicer changes this
parameter automatically.
• Menus change when [Fiber Type] is set [SM], [DS], [NZ], or [MM] mode.
Summary of Contents for KSP75-FP-005468
Page 2: ......