- 102 -
INZ-TN8ZSS-E
List for Combinations of Measureable Components, Units and Measurement ranges
Component Measuring
range
CO
0 ~ 2, 2.5, 4, 5, 10, 15, 20, 25, 50 vol%
HCl
0 ~ 10, 15, 20, 25, 50, 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
CO
2
0 ~ 2, 2.5, 4,5, 10, 15, 20, 25, 50 100 vol%
O
2
0 ~ 4, 5, 10, 15, 20, 25, 50, 100 vol%
O
2
(For use in high temp.)
0 ~ 4, 5, 10, 15, 20, 25, 50 100 vol%
O
2
(For air purge)
0 ~ 25, 50, 100 vol%
CH
4
0 ~ 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
0 ~ 2, 2.5, 4, 5, 10, 15, 20, 25, 50 vol%
NH
3
0 ~ 15, 20, 25, 50, 100, 200, 250, 400, 500, 1000, 2000, 5000 ppm or mg/m
3
HCL+H
2
O
1st comp.: HCl
0 ~ 50, 100, 200, 250, 400, 500, 1000 ppm or mg/m
3
2nd comp.: H
2
O 50
vol%
NH
3
+H
2
O
1st comp.: NH
3
0 ~ 50, 100, 200, 250, 400, 500, 1000 ppm or mg/m
3
2nd comp.: H
2
O 50
vol%
CO+CO
2
1st comp.: CO
0 ~ 2.5, 4, 5, 10, 15, 20, 25, 50 ,100 vol%
2nd comp.: CO
2
0 ~ 2.5, 4, 5, 10, 15, 20, 25, 50 ,100 vol%
CO+O
2
(ppmCO+Air purge)
1st comp.: CO
0 ~ 200, 250, 400, 1000, 2000, 5000, 6000 ppm, 2vol%
2nd comp.: O
2
0 ~ 25, 50, 100 vol%
CO+O
2
(ppmCO+High tempera-
ture O
2
)
1st comp.: CO
0 ~ 200, 250, 400, 1000, 2000, 5000, 6000 ppm, 2vol%
2st comp.: O
2
0 ~ 5, 10, 15, 20, 25, 50 vol%
CO+O
2
(vol%CO+O
2
)
1st comp.: CO
0 ~ 4, 5, 10, 15, 20, 25, 50 vol%
2st comp.: O
2
0 ~ 10, 15, 20, 25, 50, 100 vol%
Scope of delivery
•
Receiver
box
•
Transmitter
box
•
Control
unit
•
Angle adjustment mechanical section (required 2 units, one for receiver and the other for transmitter)
•
Cable between receiver unit and transmitter unit (specified length)
•
Cable between receiver unit and control unit (specified length)
•
Standard accessory set, instruction manual
Optional items
•
Spare parts for one year (ZBN1SS12)
•
Calibration gas cell (*1) (*2)
•
Cable between receiver unit and transmitter unit (For calibration) (*1)
•
Cable between receiver unit and control unit (For calibration) (*1)
•
Standard gas (ZBM), pressure regulator (ZBD)
•
Recorder (when necessary, Fuji's product type PHL/PHF, etc.)
•
Others
*1: One set of the cables and calibration gas cell are necessary for installation and annual maintenance.
*2: The length of the calibration gas cell may vary with measurement ranges.
Summary of Contents for ZSS-8 Series
Page 1: ......
Page 13: ...INZ TN8ZSS E 3...
Page 16: ...6 INZ TN8ZSS E 3 2 Wiring diagram Input output terminal...
Page 17: ...INZ TN8ZSS E 7...
Page 29: ...INZ TN8ZSS E 19 4 8 Piping system diagram Fig 4 9...
Page 42: ...32 INZ TN8ZSS E 5 2 Screen configuration...
Page 57: ...INZ TN8ZSS E 47 About Span Calibration...
Page 76: ...66 INZ TN8ZSS E...
Page 111: ...INZ TN8ZSS E 101 APPENDIX 2 CODE SYMBOLS...
Page 118: ...108 INZ TN8ZSS E DIMENSIONS IN MM...
Page 119: ......