24

Varistor

Diode

Varistor

1

2

5

3

2

1

4

3

4

5

When the impedance R is enough 

smaller than the impedance of 

 C and r

100 ohms (or more) 

 is required

r =

only

Inductive 

load

Output contact

Maintenance

1.Installation precautions

Do not install this system in a place subject to high temperatures or direct sunlight, or near a ventilator

or a heat exhaust opening.

Do not install the system in a place with high humidity or oily mist in the air.

The specified power is 100 VAC

(

50/60 Hz

)

. Never connect the machine to any other voltage.

WARNING

Never connect the system to voltages other than 100 VAC

(

such as 200 VAC,

400 VAC etc.

)

as the inside of the system may catch fire.

Never expose the inside of the housing. If the system needs to be serviced, please contact us. We are

not responsible for malfunctions or other problems caused by unauthorized service or repairs.

If smoke or smells come from the system, turn OFF the power immediately. Then please contact the

sales shop or us.

FUJI CONTROLS CO., LTD.

Technical Department :

Phone: 03-3265-5437 Fax: 03-3265-5430

E-mail: [email protected]

2.If a malfunction occurs

If you supply a no-voltage contact for the reset signal, the system may malfunction by chattering and

the voltage may drop a lot. If this happens, arrange to open the reset signal contacts after each cycle is
complete.

The load cell operates at low voltages between a few milli-volts and a few tens of milli-volts. The

measurement device has a microcomputer and an EEPROM inside. Make sure to use the device in a place
that not near high frequency electrical noise or induction noise sources

(

like large electric motors

)

,

and/or take the necessary noise-prevention steps to limit noise sources.

CAUTION

When connecting the ground terminal on this device, use only a class 3 ground.
Never share the ground for this system with any other devices or electric motors.

(

Failure to do may cause noise interference and malfunction.

)

Refer to the example below to connect a noise suppresser, capacitor, or other noise control devices.

3.Wiring checks

Periodically you must make sure to check for missing lead wires or wires sticking out of the terminal
block.

4.Checking the location of the load measurement complete sensor

In particular, if you are using the system for pressure fittings, make sure to check periodically whether or
not the sensor has moved from its original position. You can monitor the sensor operation by checking the
judgment point indicator on the front of the measurement device.

Summary of Contents for CHECK MAN CM-5

Page 1: ...er 4 Make sure to read this manual before using this unit Then keep it in a safe location The specifications of the system may be changed without prior notice FUJI CONTROLS CO LTD 1 5 6 Iidabashi Chiy...

Page 2: ...ns and performance of the system are not guaranteed and it may be dangerous WARNING Do not place any voltage across the output relay terminals If you do the machine will be damaged and the warranty wi...

Page 3: ...lower limit settings and registration patterns And it also prevents accidents caused by an unauthorized changes in the preset values APPLICATIONS PRESS FITTING Motor gears and pulleys VTR parts CD par...

Page 4: ...ent complete sensor Evaluation mechanism parts Load cell Others Back of the measurement device housing TABLE OF CONTENTS PAGE Name and function of each part on the measurement device housing 1 Operati...

Page 5: ...e display will be updated The display will be refreshed either 12 5 times at 50 Hz or 15 times at 60 Hz per second However the system is constantly measuring the actual value with an analog circuit Si...

Page 6: ...ccurately identify the peak load and measure the constantly changing load with precision regardless of the digital display operation Load upper limit digital display green LED characters This display...

Page 7: ...If the digital load display shows any characters other than zeroes or dashes press this button If any letters are displayed a ROM error has occurred If this happens see the Troubleshooting section on...

Page 8: ...is raised HI NG GO O NG One press operation cycle is complete Comparisons and results To make comparisons and present the results both a Reset signal and a Load measurement complete signal are requir...

Page 9: ...circuit to an open ON to OFF as a timing signal you should make sure that the terminals are shorted and then opened after the measurement is complete When a reset signal is input the contacts for the...

Page 10: ...tart of The part begins co mple te Pr ess ing The pre ss ram is raised cycle is reset signal C M starting a cycle up to the completion of a cycle ON OFF ON OFF complete measurement signal Press load c...

Page 11: ...er starting the cycle until the cycle is complete Since the system regards the change from an open to a short circuit OFF to ON as a valid signal make sure that the signal does not drop prematurely Ei...

Page 12: ...anual reset button is pressed Upper limit value Measured load value Contact rating 120 VAC 0 5A 28 VDC 1A resistance load GO signal output terminals a type contact continuous signal When the evaluatio...

Page 13: ...he reset signal is input Make sure it is ON before the reset signal is input operating time The load will stop being read when the load measurement complete signal is input There may be a delay in the...

Page 14: ...measurement device The contact should be designed so that the start signal level will not drop even if the operator presses the push button twice in one cycle Make sure to connect a noise suppressing...

Page 15: ...for caulking Shown on the left is an example for checking a caulking load using the timer b contacts from the press timer for press fitting operations Please make sure to design the circuit so that t...

Page 16: ...am shank designed for the load cell Tighten the two bolts evenly while being careful to align each side perfectly parallel 3 CM 5 measurement device installation There are two holes on the bottom of t...

Page 17: ...g The Digital load display displays numbers and letters When it displays four digits a decimal point will flash next to the digit which can be specified at that time On the following pages the use of...

Page 18: ...Call up the data name that you want to specify data for and then enter or change the settings See pages 20 and 23 Then turn to the Change and select each set value selection from the following pages...

Page 19: ...isplay This mode prohibits any changes in the settings The decimal point next to the 100 digit will flash 3 Press the key Now you can measure loads Digital load display Upper limit display Lower limit...

Page 20: ...the following order When or is displayed the respective upper or lower value for that pair will be displayed in the digital load display To change the upper and lower values of a pair or to change whi...

Page 21: ...hange which pair is selected press the key The pair number will change in the following order Select the pair that you want to change 2 Press the key The display will change to show the upper limit Di...

Page 22: ...ng the key Then enter the correct number by using the key If you want to change the lower limit value go to step 8 If you don t need to change the lower limit value press the key Then the change will...

Page 23: ...he procedure above changes the upper and lower limits for pair 1 By referring to this set of steps you can change the upper and lower values for each pair to meet your actual work requirements NOTE Th...

Page 24: ...eys in that order again Once a limit pair number has been selected the upper and lower values stored in that pair will be displayed Setting the power supply frequency If your power company supplies 50...

Page 25: ...al load display will alternate between and If you are using the system in an area with 60 Hz power select 5 Press the key That completes the power frequency setting Now the system is ready to make mea...

Page 26: ...shock when workpieces hit each other select this mode The system samples and displays the load constantly If the load decreases to zero while making a measurement the display will also show zero After...

Page 27: ...it display means that the end measurement mode is selected 5 Press the key That completes the measurement mode change If the digital load display shows only dashed lines press the reset push button 6...

Page 28: ...the reset signal the system may malfunction by chattering and the voltage may drop a lot If this happens arrange to open the reset signal contacts after each cycle is complete The load cell operates a...

Page 29: ...easurement device The digital display doesn t work properly Some LEDs may be faulty You can find faulty LEDs during the ROM check procedure when turning ON the power At that time the device will light...

Page 30: ...the cable connected properly to the 5 pin metal connector on the tip of the load cell Is a reset signal input after a workpiece is evaluated The display does not continue to show a Is the load measure...

Page 31: ...27...

Page 32: ...he tapped holes on the bottom do not insert screws that go deeper than 10 mm inside the housing cut the panel using the dimensions given below The numbers in parenthese are for MEASUREMENT DEVICE DIME...

Page 33: ...The units shown in curly brakets are for refence purposes only Shield Input Output Output Input Load surface M6 through hole Load surface Load surface cable 2 meters Load surface through hole cable 2...

Page 34: ...device 4 To terminal of terminal block on the back of the measurement device 2 If you want to use an emergency stop push button connect it to terminals 1 and 2 Normally SV 2 is not used It is used fo...