19
−
10. Press the
key.
Each time you press the
key, the number in the 10
2
digit location will change in the following order:
"
0→1→2→3→4→5→6→7→8→9→0
"
Change this digit to " ."
11. Repeat the operations in steps 8 and 9 on the previous page. Set the values of the 10
1
and 10
0
digits to "2" and "5" respectively. ........
After all the settings are complete, the displays will look like
the following.
Digital load display
Lower-limit display
←
Pair number display
The initial value of "100" is changed to "225."
1
2. Press the
key.
--- Now, you can measure loads.
Digital load display
←
Upper-limit display
←
Lower-limit display
←
Pair number display
The procedure above changes the upper and lower limits for pair 1. By
referring to this set of steps, you can change the upper and lower values for
each pair to meet your actual work requirements.
NOTE:
①
The display is designed to ignore attempts to make the upper limit larger than 3000. If you
enter a number larger than 3000, the system will change it to back 3000.
②
If you enter a number for the upper-limit value that is smaller than the lower-limit value,
or any value for the lower-limit that is larger than the upper-limit value, "
" will be
displayed. Then, approximately three seconds later, the system will let you correct the error
setting. Reenter a correct value.
③
Anytime you want to stop changing the settings, press the
key. The system will return
to the measurement mode immediately.