Method for selecting the measurement mode
This section describes the method for selecting either one of the
measurement modes used to compare the measured load with the upper and
lower limit values. You can select either
the peak value mode
*
or
the end value
mode*
.
*
Peak value mode
........This is selected as the default mode when the system is delivered.
・
The system will sample the measured values in real time and update the peak value. The highest peak
value is displayed, until the load measurement complete signal is input.
・
After the load measurement complete signal is input, the system will store the highest value between the
reset signal input and the load measurement complete signal input. Then the system compares that value
with the upper and lower values that were specified beforehand. Finally, it decides whether the
measured value is acceptable or unacceptable.
*
End value
(
constant load measurement
)
mode
・
This mode releases the peak hold function. If you want to avoid the extreme load readings caused by the
shock when workpieces hit each other, select this mode.
・
The system samples and displays the load constantly. If the load decreases to zero while making a
measurement, the display will also show zero.
・
After the load measurement complete signal is input, the system will store the current value. Then the
system compares the stored value with the upper and lower limits that were specified beforehand.
Finally, it decides whether the measured value is acceptable or unacceptable.
1. Press and hold the
and
keys for approximately 1 second. (Press the
key, first.)
At this time, you cannot measure loads. Press the
key again when you want to return to the
measurement mode.
Digital load display
Lower-limit display
↓
The decimal point next to the 10
0
digit will flash.
"
" is the default mode when the system is delivered. If you select the mode which prohibits changes,
"
" will be displayed.
2. Press the
key.
Each time you press the
key, the digital load display will show the mode numbers in the following
order: "
→
→
→
→
". Select "
" on this display.
Digital load display
Lower-limit display
3. Press the
key once.
Digital load display
Lower-limit display
←
"
" means that you can select
the measurement function type.
↓
"
" means that the peak measurement mode is selected.