23.6 Protection setup
It is possible to set 2 different kinds of password:
Password Protection Setup 1/2
Disabled
Enabled
User password
Change
Change password
Block adjust paramet
Block engine
Password Protection Setup 2/2
Disabled
Enabled
Tuner password
Change
Change password
This password locks:
- Injection Table Adjust
- Ignition Table adjust
- Other Functions
- Engine Settings
- Sensors and Calibration
- File Manager
User password (FT500 only)
Enabling the user password allows the setup of 3 different protection
behaviors:
•
Protection disabled:
this option must be selected when the user
wants to insert a password but keep free access to all menus. It
must be chosen to avoid that any password is inserted without
the user’s consent.
•
Protect adjust parameters:
with this option, all menus are
protected against changes. Open access is given only to the
information read on the dashboard screen, and engine operation.
•
Block engine start:
this option blocks the engine start only.
When touching the screen to enter the menu and a password has
already been set and protecting the menus, the system will request it
to be inserted to open access.
Type the current password on the screen for access to be given until
injection is restarted or the password is disabled.
Tuner Password
This password blocks only the “Injection tables adjust”, “Ignition
tables adjust”, “Other functions”, “Engine setup” and the
“Sensors and calibration” menus, letting open access to other
menus. When this password is active, it is not possible to change
any fuel or ignition map.
The tuner password protects the access through FTManager also.
IMPORTANT:
This ECU leaves FuelTech factory with all
passwords disabled. Once inserting a protection
password, the user will be blocking other people
from accessing the ECU and even blocking him/
herself. When choosing a password, make sure
you will remember it, as, for safety matters,
this password can only be changed at FuelTech
factory (being the owner in charge of shipping
the ECU along with its purchase invoice).
Measurement Units 1/2
Pressure unit
bar
Psi
kPa
Temperature unit
°C
°F
Measurement Units 2/2
O2 Sensor unit
Lambda
AFR
Speed unit
kph
mph
23.9 Demonstration mode
The demonstration mode can be enabled to show the main features
of FuelTech FT500 and its working. You can set the waiting time to
get in the demo mode. To exit, just touch the screen.
23.10 Touchscreen calibration
This function allows the touchscreen recalibration, use it whenever
you notice the screen is unresponsive. Calibrate the screen with you
finger or with a pen.
23.11 Serial number and software version
In this menu, it is possible to verify the software version and the
equipment’s serial number.
Make sure you have these numbers in hand whenever the FuelTech
Technical Support is contacted to facilitate and optimize the assistance.
23.7 Clear peaks
At the Dashboard, values read by the sensors connected to the module
are displayed in real time. On the bottom of each box on the display,
the minimum (on the left) and maximum (on the right) values read
by the sensor are shown.
It is possible to clear this data by accessing the option “Clear Peaks”,
under the “Interface Settings” menu.
Serial number and version 1/2
002814.0023041.035
Serial number
Software Version
1.00
General
version
Compatibility
version
1.00
Serial number and version 2/2
1.00
Bootloader:
1.00
Bootloader:
ECU:
2.00
Interface:
1.00
Software Version
1.00
General
version
Compatibility
version
1.00
Startup screen selection
Open the main menu after startup
Open the dashboard after startup
Open the favorites menu after startup
Configuração do painel de instrumentos
Seleção da tela principal
Clear peaks
Configuração de favoritos
Configuração de favoritos
Interface settings
Are you sure you want
to clear peaks?
Warning!
Yes
No
23.8 Measurement units
In this menu it is possible to change the measurement unit for some
parameters as pressure, temperature, speed and O2 readings.
Pressure Units
: bar, PSI ou kPa;
Temperature units
: °C or °F;
O2 sensor units:
Lambda, AFR Gasoline or AFR Methanol;
Speed units:
km/h ou mph