FT500 SFI / FT500LITE SFI
56
Fuel tables adjust
Next, is a 3D table of O2 closed loop targets versus RPM and MAP.
It has up to 16x16 cells that can be edited through the PC Software.
There is also an option to setup a different O2 target for burnout
mode, 3-step and 2-step. This target is a fixed value, no matter the
RPM or MAP pressure.
The next screen (6/9) is only shown when the idle is TPS based. Set
a target for idle condition (TPS=0%).
-0,90 bar
Minimum
Maximum
-10,0
%
10,0
%
O2 closed loop 7/9
O2 closed loop control limits is a 16 points (8 columns and 2 lines)
table, totally editable, by TPS or MAP, which defines the actuation limits
of O2 closed loop, avoiding the control to remove or add too much
fuel in certain situations.
Auxiliary O2 closed loop:
Aux by time (2-step):
This feature allows the creation of a 16 points time based O2 target
table after the 2-step deactivation, which will overwrite the main O2
target table during the time setup on this auxiliary table. To trigger the
2-step, TPS must be above 50% or RPM must hit the 2-step rev limiter.
O2 closed loop 8/9
Disabled
Enabled
Time based (2-step)
Time based Pro-N.
RPM based Pro-N.
Set time based lambda
target after 2-setp
release
Auxiliary closed loop
0,00 s
0,82
λ
O2 closed loop 9/9
Aux Pro-Nitrous by RPM:
This feature allows the creation of a 16 points RPM based O2 target
table to each Pro-Nitrous stage, which will overwrite the main O2 target
table while the auxiliary control is on. This feature is only enabled when
all Pro-Nitrous requirements are fulfilled.
Disabled
Enabled
Time based (2-step)
Time based Pro-N.
RPM based Pro-N.
Set
based lambda
RPM
target to each
Pro-Nitrous stage
O2 closed loop 8/9
Auxiliary closed loop
2000
RPM
3000
1000
Stages
3
2
1
3
0,82
0,82
0,82
2
1
0,82
0,82
0,82
0,82
0,82
0,82
λ
+
-
O2 closed loop 9/9
Aux Pro-Nitrous by time:
This feature is a 16 points time based O2 target table to each Pro-
Nitrous stage, which will overwrite the main O2 target table while the
auxiliary control is on. This feature is only enabled when all Pro-Nitrous
requirements are fulfilled.
0,50
s
1,50
0,00
Stages
3
2
1
3
0,82
0,82
0,82
2
1
0,82
0,82
0,82
0,82
0,82
0,82
λ
+
-
O2 closed loop 9/9
Disabled
Enabled
Time based (2-step)
Time based Pro-N.
RPM based Pro-N.
Set
based lambda
RPM
target to each
Pro-Nitrous stage
O2 closed loop 8/9
Auxiliary closed loop
17.5 Idle speed by TPS table
TPS idle fuel injection table
1250 RPM
1,950
ms
This menu is only available when the idle speed is set up by TPS. The
injection time is adjusted according to the engine RPM.
17.6 Acceleration fuel enrichment and decay
Fuel Injection Tables Adjust
Mapa de lambda para malha fechada
Accel fuel enrich and decay
Engine temp. compensation
Intake Air Temp. compensation
Battery voltage fuel compensation
Accel fuel enrich and decay 1/4
4,000
ms
to:
1000
RPM
to:
1 00
, 0
ms
6300
RPM
Max fuel on pump
Accel fuel enrich and decay 2/4
Accel fuel pump reduction
above
50%:
TPS
-50,0
%
TPS MAP
/
variation for
maximum fuel pump:
40,0
%
Accel fuel enrich and decay 3/4
Cold engine fuel
pump enrichment
+350
%
Accel fuel enrich and decay 4/4
Fuel decay on max pump
2,080
ms
to:
1000
RPM
to:
0,930
ms
6300
RPM