Operating Instructions
rain[e]LP FTS
14 Technical
Data
SDI-RAINE-HYDRO
Measurable precipitation
types:
liquid
Measurement principle:
weighing with automatic self emptying
Operating temperature:
0...+70 °C
Storage temperature:
-40..+70 °C
Collecting area:
200 cm²
Amount measurement
range:
without limitation (0.005…
∞
mm)
Amount resolution:
0.001 mm (pulse output: 0.01 mm)
Amount accuracy:
0.1 mm or 1 % at < 6 mm/min
and 2 % at
≥
6 mm/min
Intensity range:
0…
1
0 mm/min resp. 0…
6
00 mm/h
Intensity resolution:
0.001 mm/min resp. 0.001 mm/h
Intensity accuracy:
0.1 mm/min resp. 6 mm/h-
Dimensions:
292 mm x 190 mm (h x d),
see dimensional drawing
Suitable for mounting:
Ø 60 mm
Weight:
approx. 2.5 kg
Standards:
WMO-No. 8 • VDI 3786 Bl. 7 • EN 61000-2, -4 • EN 61000-4-2, -3, -4, -5, -6, -11 • NAMUR NE-21
Protection class load cell: IP67
Current consumption:
typ. 6.9 mA at 12 V power supply
Supply voltage:
9.8...
3
2 V DC
Signal outputs:
•
SDI-12
•
linearised, bounce-free pulse output signal
or
status output (con
fi
gurable, e.g. ‘Rain YES/NO’ ’)
◦
Pulse 1 (galvanically isolated, open collector): Max. 24 V DC / max. 0.05 A / max. 0.5 W
◦
Pulse 2 (open collector):
Max. 24 V DC / max. 0.1 A / max. 0.5 W
27
T
oll-free
Local
1.800.548.4264
250.478.5561
service
@
ftsinc.com
Technical support portal: http://support.ftsinc.com
Canadian Headquarters:
1065 Henry Eng Place
Victoria, BC | V9B 6B2 | Canada
www.ftsinc.com
CONTACT INFORMATION
(
0...+158
°F
)
(-40..+158°F)
(2.4")
(11.5" 7.5")
(5.5 lbs)
SDI-RAINE-HYDRO
USER MANUAL
700-SDI-RAINE-HYDRO Rev1 03 Mar 2021
Part# 21184