User’s manual · TFF 310 CI
- 6 - TFF 310 CI version_en_2.0 FTE maximal
5. Set Output channel
In this option you can configure the different parameters of the cable signal.
- Channel standard: It allows you to select the channelling of the cable
signal standards. Options: BG, BG, PAL BG IT, LL, M NTSC, PAL M,
PAL N, PAL DK , PAL I, BB_AU, DK PAL, L PAL.
- Channel: Output channel of the cable modulation. When you select the
output channel, the field “Frequency (MHz)” will be modified
automatically, adapting itself to the selected channel. Options: C2-C69.
- Frequency (MHz): Output frequency of cable modulation. When you
modify this field, the field “Channel” will be also modified, indicating the
channel equivalent to the selected frequency in the case that this
frequency corresponds to the frequency of a channel.
Options: 47-862 MHz.
- Level: Regulation of the output level of the modulated signal.
Options: 0-15dB.
- Calibration: Allows the realization of two tests in order to verify the
correct running of the device.
- Deactivate output: It allows activating or deactivating the output of
regenerator.
- Switch output to CW: It allows activating or deactivating the DVB-T /
DVB-H modulation, allowing visualizing the carrier without modulation in
the selected frequency.
6. System
This option provides information of the regenerator.
- System logfile: In this field are indicated the registered events in the
module.
- Read log: It allows reading the registered events in the
module.
- Clear log: It allows deleting all events stored until this
moment.
- Export log to USB: It allows you to export all events
registered to the connected USB device.
- NM low Limit (dB): An event of error will be recorded when
the value of Noise Margin is lower than the set value.
- NM high limit (dB): Once the event of error is recorded (Noise
Margin < Limit Lower NM), this will be Noise Margin value that
will have to be exceed so the module stops being in error.
- Clear log all devices. It allows deleting the events report of all
the interconnected modules.
- Factory default: This option restores the values by default of the
regenerator.
- System information: It allows you to visualize the basic information of
the module: model, no of series, firmware version, etc.
- Settings: This option allows saving and loading the configuration of
the module, carrying out firmware update or making an adjustment of
the time and date of the module.
-
Clock:
- Set Date and time: Setting of the date and time of
transmodulator. It is appropriate to maintain these
parameters set in order to have the registration of
errors linked to the current time and date.
- Set date/time all devices: Loading the current date
and time of the module in the rest of interconnected
modules.
- Alias:
- Write alias: It allows you to assign a name/alias to
the module you are programming. Option only available
when the Alias Auto option is configures as “none”
(manual mode).
Summary of Contents for TFF 310 CI
Page 1: ...TFF 310 CI USER S MANUAL...